the cold room at night
the compressor that stops before dawn and the product nobody sees until the morning shift
AstreaIoT · sensors that alert you on WhatsApp when something on your site goes out of range
For distributors of meat, dairy and refrigerated groceries · NOM-251
A night with the compressor stopped or a freezer door left ajar shows up in the morning, when the product is already out of range. And when the chain or the supermarket receives, it asks for the temperature log: without it, it is your driver’s word against the receiver’s. AstreaIoT watches every cold room and freezer in the warehouse, alerts on WhatsApp whoever can act and builds the log by itself.
the compressor that stops before dawn and the product nobody sees until the morning shift
a freezer door left ajar at night, and the temperature rising with nobody watching
the receiving chain asks for the temperature record; without it, you lose the argument
The warehouse’s cold rooms and freezers come in from the first site. The truck’s box and the route with temperature are delivered per project, on the same platform and with the same log.
In every cold room and freezer of the warehouse: a temperature sensor, a door-opening sensor and a current meter on the compressor. If a compressor works too hard, you see it weeks before it fails.
An opening sensor on every door: if it stays open more than 5 minutes the alert comes, and at 15 it steps up, with the temperature already climbing.
The temperature record: one PDF per room with one row per hour, to hand to the chain or the supermarket when they ask.
A cellular sensor in the refrigerated box with temperature, door and location, or a mobile gateway for several zones of the box. Delivered per project: it needs a SIM and coverage on your route.
point by point
From the cold room to the customer’s dock: in each place, what is watched and who gets the alert.
example distribution center · the truck’s box comes per project
hover a row · click to pin it · esc to let go
what goes on each piece of equipment
Five points in a distribution warehouse and where the sensor goes on each. All of them go on the outside: no equipment is replaced.
measures: the temperature inside the room, and every time the door opens.
installed: the probe on the wall, away from the evaporator; the contact on the door frame.
measures: when the roll-up door opens and closes, with its time.
installed: at floor level, next to the track, with no wiring.
measures: the current of each compressor: if one stops, you see it before the temperature.
installed: clamped around the cables, without cutting them.
measures: the frozen goods' temperature, at −18 °C, and every time the door opens.
installed: the probe on the wall, away from the evaporator; the contact on the door frame.
measures: it does not measure; it gathers the warehouse’s readings and sends them to the dashboard.
installed: on a mast, with the antenna clear above the roof.
One night at the warehouse, with sample data
The meat cold room's compressor has drawn more than 15 % over its baseline for two weeks. A recommendation is left in the dashboard: schedule the maintenance, while the room is still in range.
likely cause
It has drawn more than 15 % over normal (11.2 A) for 2 weeks: usually low refrigerant, a dirty condenser or a worn compressor.
what to do
Schedule the compressor maintenance: the refrigerant, the condenser cleaning and the wear, before it fails.
Oct 18 · the room is still in range
The blocked condenser makes it work too hard. At 01:30 it passes 15 A, 125 % of its nameplate, and the room starts to climb from 2.2 °C.
| Day | Minimum | Maximum | Out of range |
|---|---|---|---|
| mar 27 oct | 12.6 A | 12.7 A | — |
| mié 28 oct | 11.7 A | 15.6 A | 55 min |
With the warehouse closed. It says which unit, what is happening and what to check first, and it is answered from the same chat. If nobody answers, it moves up to the next person in the chain.
The app keeps what was done and who did it. At 02:25 the compressor is back at 11.8 A, and the room, which reached 3.8 °C, goes back to 2 °C without leaving its range.
overload
Compressor · meat cold room
Refrigeration · CEDIS Norte
CriticalIt has drawn more than 15 % over normal for 2 weeks: usually low refrigerant, a dirty condenser or a worn compressor.
› The product first: do not open the room. Check the condenser and the refrigerant; if the current does not drop, call the technician.
02:10Acknowledged · maintenance lead
02:25Condenser cleaned; the compressor at 11.8 A
the same night, two records
The room's log sheet is filled in three times a day. On October 27 the three readings were fine, and from 01:20 to 03:30 the meat cold room climbed to 3.8 °C with the compressor overloaded. The sheet does not see it; the sensor does, and the current alerted first.
| Day | Minimum | Maximum | Out of range |
|---|---|---|---|
| mar 27 oct | 2.0 °C | 3.0 °C | — |
| mié 28 oct | 2.0 °C | 3.8 °C | — |
meat cold room · October 27 to 28 · sample data
| the hand log sheet | the sensor | |
|---|---|---|
| Readings in the day | Three, by hand, at 8:00, 14:00 and 20:00. | All day and all night, with nobody taking them. |
| The climb in the early hours | Not there: nobody writes at that hour. | From 2.2 to 3.8 °C between 01:20 and 02:25, without leaving 0 to 4 °C. |
| The compressor | Nobody knows it is working too hard. | At 01:35, 15.6 A against a 12 A nameplate: the alert, before the room left its range. |
| When the customer complains | Your word against theirs. | The room's hourly record, with the temperature the load left at. |
| A missing reading | The gap stays, and the finding is yours. | The record counts the hours without a reading for each unit. |
What we see in a warehouse, with the reading that gives it away before it costs. Sample data.
The room starts to climb with the door shut and the compressor drawing no current: the alert comes when it passes 4 °C, with the likely cause, a power cut or a stopped compressor.
points 1 and 3 · cold room and panelThe contact marks the door open: the alert comes at 5 minutes and steps up at 15, with the temperature already climbing. It says which door and since when.
point 4 · freezer roomThe current meter learns the compressor's baseline: if it runs more than 15 % over for weeks, a recommendation is left to schedule the maintenance before it fails.
point 3 · panelThe temperature record of the room the load left from: one PDF per unit, one row per hour, no gaps at night, ready in minutes.
point 1 · cold roomTechnical visit: inventory of cold rooms, freezers, doors and panels, and what each customer asks for at receiving.
Sensors in every cold room and freezer, a current meter on each compressor and a gateway that stores readings while there is no connection, without stopping operations.
Ranges per room, a day rule and a night rule for the doors, and who gets each alert on WhatsApp.
When you want the route with temperature: sized per unit, with the SIM and coverage of your routes.
AstreaIoT is the monitoring platform of Astrea Technologies, an engineering and software company in Monterrey since 2018. The sensor network is ours, we build the platform and the app, and the hardware comes from manufacturers we work with directly. We install in northern Mexico with our own team and in the rest of the country with partner integrators.
Hardware from Milesight, Dragino and Tektelic; stock in Mexico through Syscom.
Not in today’s box: the truck’s box and the route with temperature are delivered per project. It is sized per unit, with a cellular sensor in the box or a mobile gateway, and needs a SIM and coverage on your routes.
Yes. The sensors are external and mount on any equipment, without touching the refrigeration system and without stopping operations.
The gateway stores the readings while there is no connection and uploads them when it comes back. The sensors keep recording and everything syncs on reconnect.
Each sensor ships with its factory calibration report. It is not a certificate from a lab accredited by ema: for the inspection, your calibrated thermometer remains the reference, and the platform keeps each device’s certificate in its calibration record. Recalibration every 12 months: we keep the calendar.
The refrigerated warehouses and 3PL page covers third-party rooms and the report for each brand. It is the same platform.
Thirty minutes. You tell us how many cold rooms and freezers you have, how many units go out on routes and what each customer asks for at receiving. We hand you a quote per warehouse and what goes per project.