four zones · infrastructure for absolute continuity.
A C5/C4 or public-safety station has the same four building-infrastructure fronts as a data center, but with higher criticality: absolute operational continuity (UPS + generator), NOC IAQ for staff in long shifts, auditable perimeter, access to critical rooms (dispatch, archive).
UPS + generator + continuity
Current meter (current meter) on UPS line + UPS-room temperature sensor + generator current meter + diesel sensor + generator-room temperature sensor. 24/7 continuity guaranteed · alert before full discharge · operative always connected.
IAQ + NOC conditions
CO₂ / PM2.5 / VOC + temperature + humidity sensor in dispatch hall + operational areas. Staff in long shifts (12h+) require optimal conditions for concentration. Automated STPS compliance.
perimeter + critical access
Perimeter PIR sensor of the center + door sensor on critical rooms (servers, archive, dispatch, evidence). Immutable record of who enters where · nighttime coverage · traceability for internal audit.
sub-metering + technical environment
main-panel meter sub-metering per operational area (dispatch, NOC, training rooms, offices) · CFE GDMTH PF analysis · leak sensor in electrical + server rooms · electrical-room temperature sensor. Granular budget + defended technical environment.
Out of scope: CCTV network or NMS health monitoring (SolarWinds, PRTG territory). AstreaIoT covers building infrastructure + operational environment · does not compete with network or video-surveillance monitoring.
what we protect · what we prevent.
- +UPS + generator always operational · C5/C4 with absolute continuity · operations without outage
- +NOC IAQ documented · staff in long shifts with optimal conditions · STPS compliance
- +Critical-room access audited · documented traceability · internal audit backed
- +Granular CFE sub-metering · transparent per-area operational budget
- +Defended technical environment · electrical + server rooms with leak + temperature sensors
- ✕C5/C4 down in emergency · lives at risk · national scandal + institutional liability
- ✕NOC with deficient IAQ · fatigued staff · operational errors in critical moments
- ✕Unauthorized access to server room or archive · breach with legal consequences
- ✕CFE GDMTH surcharge · operational budget eroded without visibility
- ✕Leak or overheating in technical room · server outage · institutional scandal
eight use cases · four critical areas.
for the C5/C4 director.
C5/C4 Director + Operations Chief. Two cases · UPS with unmonitored load (blackout surprise), generator off during emergency. Guaranteed absolute operational continuity.
for the dispatch chief.
Dispatch Chief + HR Lead. Two cases · elevated CO₂ in dispatch hall with long shifts, thermal conditions affect staff concentration. Automated STPS for critical operations.
for the institutional security officer.
Institutional Security Officer + Internal Audit. Two cases · unauthorized access to server room, evidence archive without access traceability. Coverage for internal audit and compliance.
for the institutional CFO and technical lead.
Institutional CFO + Technical Lead. Two cases · CFE GDMTH spending without per-area sub-metering, undetected server-room leak. Transparent budget + defended technical environment.
three compliances · one platform covers all three.
Federal/state LAASSP procurement · multi-year contracts · award-eligible service. Compatible with existing systems (CCTV, NMS, ITSM) via Custom Integration · does not compete with network or video monitoring.
from sensor to report · every five minutes · without human intervention
Five steps. They run in parallel across all your sites, all the time. When something crosses a threshold, the flow completes in under five minutes — alert delivered, response logged, inspector-ready evidence captured.
measure
Sensors measure temperature, humidity, current, door-open, leak and other magnitudes every five minutes — no operator required.
detect
The system compares each reading against the threshold configured per recipe · per site · per equipment. Threshold crossing triggers the flow.
alert
The alert routes to the right person via WhatsApp, email or push · per role and schedule configured.
respond
The operator acts from the dashboard or mobile app. The corrective action goes into an immutable log with timestamp + signature.
audit
Everything becomes part of the audit package · time series, critical events, corrective actions, NOM report ready in two clicks.
Five steps · no manual operators · no paperwork · no gaps.
five phases · per command center or station.
site survey
2 daysTechnical visit + inventory of UPS + generator + critical rooms (servers, archive, dispatch) + operational areas · per-stage deployment plan with zero outage.
physical installation
3-4 daysSensors on UPS + generator + NOC IAQ + perimeter + critical access + sub-metering + technical-room leak + gateway with 32-hour backup · overnight work or maintenance windows · zero operational outage.
configuration + integration
2 daysPer-area thresholds · integration with existing NMS/ITSM via Custom Integration · alerts escalated per severity and per role · internal-audit report templates.
team training
1 dayC5/C4 Director + Dispatch Chief + Institutional Security + CFO + Technical Lead · each role trains on alert and report flow.
30 days of support + first internal audit
30 daysAstreaIoT specialist available · first monthly continuity + IAQ + access report · first internal audit backed with data · procedure validation.
For multi-center systems (state C5 + municipal C4 + police/fire stations), cross-center dashboard with regional executive view.
common questions · before the quote.
does AstreaIoT compete with C5/C4 NMS or CCTV system?
No · AstreaIoT covers building infrastructure + operational environment. NMS (SolarWinds, PRTG) keeps monitoring network and CCTV remains video surveillance. AstreaIoT adds UPS + generator + IAQ + perimeter + physical access · integration via Custom Integration.
does it comply with federal C5/C4 continuity standards?
Yes · 99.99% command-center availability backed with continuous UPS + generator + environment data. Monthly auditable report available for internal audit + ASF · compatible with federal SSPC policies.
is C5/C4 operational confidentiality respected?
Zero additional cameras. Only aggregated ambient sensors + binary sensors. Operational data isolated per contract · role-based dashboard access · complies with institutional security policies.
does it integrate with existing ITSM (ServiceNow, BMC, Remedy)?
Yes · via Custom Integration. Alerts + automatic tickets to ITSM · automated escalations per severity. NOC operates with familiar flow · zero additional training for ticket system.
what about police/fire stations without own internet?
Gateway with cellular backhaul or solar for stations in rural zones · compatible with stations without own Ethernet.
is it billed as federal/state CapEx or multi-year service?
Both models · CapEx (organization buys) or multi-year operational service (typical 3-5 years). Procurement via federal/state LAASSP · 5-year contracts supported.
is the internal-audit report pre-formatted?
Yes · pre-configured templates for internal + ASF + continuity-control audits. Downloadable PDF with immutable timestamp · specific templates for C5/C4 + police + fire.