your tower or POP · site infrastructure measured and watched.

For Mexican tower companies, telecom carriers, and ISPs: per-remote-site monitoring — CFE energy + generator fuel, shelter IAQ, radio-equipment AC, nighttime perimeter, critical cabinet door, rectifier current. One platform · hundreds or thousands of sites · remote operation from the NOC.

what's at stake
site downcell out of service = thousands of users affected · carrier SLA
copper thefttowers are constant theft target · replacement + outage
overheated shelterradio equipment fails · tower operation interrupted
>./zonas·I · four critical zones · each site

four zones · replicated in every tower or POP.

A telecom tower or ISP POP has the same four operational fronts at each site: CFE energy + generator + fuel, shelter AC + IAQ for radio equipment, perimeter + access to cabinets, rectifier current and battery bank. AstreaIoT replicates the same dashboard per site · NOC sees the whole network.

01

energy + fuel + generator

Current meter (current meter) on CFE line + generator + three-phase meter (main-panel meter) if applicable. Ultrasonic level sensor (ultrasonic level sensor) on diesel tank. Generator current-signature analysis for predictive maintenance. Sites always ready.

02

shelter AC + IAQ

Temperature + humidity sensor inside shelter · radio-equipment overheating alert. Current sensor (current meter) on AC unit · efficiency analysis. Smoke detector in shelter. Radio equipment protected from extreme conditions.

03

perimeter + cabinet access

Perimeter PIR sensor · door sensor on critical cabinets (rectifier, batteries, switch) · shelter door sensor. Copper anti-theft + vandalism + documented authorized technical access.

04

rectifier + batteries + UPS

current meter on rectifier line · battery-room temperature sensor · leak sensor in electrical room. Battery bank and rectifier state always visible · failure detected before service outage.

Out of scope: RF / spectrum monitoring (Anritsu, Viavi, Keysight specialty) · backhaul fiber monitoring (NMS territory · SolarWinds, PRTG). AstreaIoT covers physical + environmental site infrastructure · does not compete with network-layer or RF monitoring.

>./valor·II · the platform · against five concrete losses

what we protect · what we prevent.

what we protect
  • +Site always operational · monitored generator + fuel · carrier SLA protected
  • +Radio equipment protected from extreme conditions · continuous shelter AC + IAQ
  • +Copper anti-theft · perimeter + cabinet door watched
  • +Generator + rectifier predictive maintenance · zero unexpected outage
  • +NOC with visibility of hundreds or thousands of sites from a single dashboard
what we prevent
  • Site down from generator out of fuel · broken SLA · thousands of users affected
  • Radio equipment damaged from overheating · expensive replacement + service outage
  • Copper theft or vandalism · replacement + temporary outage · carrier image
  • Rectifier or battery fails without warning · site falls when CFE cuts
  • Technician dispatch to remote site without diagnosis · unnecessary trips
>./casos·III · eight situations · four areas

eight use cases · four critical areas.

>./energy-fuel·sección A

for the network operations director.

Network Operations Director + NOC Lead. Two cases · generator without fuel when CFE cuts, fixed-calendar generator maintenance. Guaranteed operational continuity.

#what happenshow we detect itprotected value
01
Stand-by generator without fuel when CFE cuts · site falls
Ultrasonic level sensor on diesel tank + current meter generator · NOC alert
Site always operational · diesel reorder scheduled · carrier SLA met
02
Generator maintenance by fixed calendar · unexpected failure
Generator current-signature analysis · detects degradation 2-4 weeks ahead
Data-driven maintenance · technician dispatched with plan · zero unexpected outage
>./ac-shelter·sección B

for the site infrastructure lead.

Infrastructure Lead + Field Operations. Two cases · overheated shelter in desert zone, AC unit with efficiency failure. Radio equipment always in operational conditions.

#what happenshow we detect itprotected value
03
Overheated shelter in desert zone · radio equipment at risk
Temperature + humidity sensor inside shelter · threshold alert
Radio equipment protected · AC adjusted or repaired in time · continuous operation
04
AC unit with efficiency failure · high electrical spending
current meter on AC line · vs baseline efficiency analysis
Scheduled AC maintenance · electrical spending reduced · equipment protected
>./perimeter-copper·sección C

for the site security lead.

Site Security Lead + Vigilance. Two cases · copper theft in remote tower, unauthorized technical access to critical cabinet. Continuous anti-theft and access traceability.

#what happenshow we detect itprotected value
05
Copper theft in remote tower · replacement + outage
Perimeter PIR sensor + cabinet door sensor · immediate NOC alert
Theft detected in minutes · vigilance dispatched · copper protected
06
Unauthorized technical access to critical cabinet · sabotage or error
Cabinet door sensor + who/when/duration record
Access traceability · audit facilitated · sabotage prevented
>./rectifier-batteries·sección D

for the power systems lead.

Power Systems Lead + Field Engineering. Two cases · rectifier with silent degradation, battery bank with thermal failure. Power systems state always visible.

#what happenshow we detect itprotected value
07
Rectifier with silent degradation · failure during CFE outage
current meter on rectifier line · signature analysis · degradation alert
Scheduled maintenance · replacement before failure · site always with energy
08
Battery bank with thermal failure · reduced capacity without warning
Battery-room temperature sensor + current meter · anomaly alert
Battery state visible · scheduled replacement · reliable backup
>./noms·IV · regulations and SLAs that apply

three compliances · one platform covers all three.

Carrier SLA (Telcel, AT&T, Movistar)
what it requires
99.95%+ per-site availability · documented response time · incident evidence for claims.
how we deliver
Immutable per-sensor log · per-event timestamp · monthly per-site report for the carrier client.
IFT (Federal Telecom Institute)
what it requires
Compliance with operational obligations + tower conditions + IFT reports.
how we deliver
Continuous site infrastructure report · documented compliance · IFT audit backed.
NOM-001-SEDE + NOM-018-STPS
what it requires
Site electrical safety + field-technician conditions during maintenance.
how we deliver
Electrical-room temperature sensor + shelter IAQ sensor + smoke detector · documented compliance.

For tower companies (American Tower, Sitios Latinoamérica, Telesites), cross-portfolio dashboard with per-site incident ranking · per-carrier-client award-eligible service.

>./workflow·how the data travels

from sensor to report · every five minutes · without human intervention

Five steps. They run in parallel across all your sites, all the time. When something crosses a threshold, the flow completes in under five minutes — alert delivered, response logged, inspector-ready evidence captured.

01

measure

Sensors measure temperature, humidity, current, door-open, leak and other magnitudes every five minutes — no operator required.

02

detect

The system compares each reading against the threshold configured per recipe · per site · per equipment. Threshold crossing triggers the flow.

03

alert

The alert routes to the right person via WhatsApp, email or push · per role and schedule configured.

04

respond

The operator acts from the dashboard or mobile app. The corrective action goes into an immutable log with timestamp + signature.

05

audit

Everything becomes part of the audit package · time series, critical events, corrective actions, NOM report ready in two clicks.

Five steps · no manual operators · no paperwork · no gaps.

>./despliegue·V · five phases · from kickoff to first NOC with visibility

five phases · per site.

01

site survey

half day per site

Technical visit + inventory of generator, AC, shelter, rectifier, batteries, cabinets · per-site deployment plan.

02

physical installation

half day per site

Energy + fuel + AC + shelter IAQ + PIR + cabinet door + rectifier + batteries sensors + gateway with 32-hour backup · no service shutdown · 1 day per site.

03

configuration + NOC integration

1-2 days

Per-site thresholds · integration with central NOC (ServiceNow, BMC Remedy, proprietary systems) · alerts escalated per severity and per carrier client.

04

team training

1 day

Operations Director + NOC Lead + Power Systems + Security + Field Engineering · each role trains on flow.

05

30 days of support + first NOC with visibility

30 days

AstreaIoT specialist available · NOC with full visibility of hundreds/thousands of sites · first carrier audit backed.

For large portfolios (thousands of sites), per-region deployment with monthly waves · time-to-NOC-visibility 30-90 days per scale.

>./faq·VI · common questions before the quote

common questions · before the quote.

does it integrate with existing NOC (ServiceNow, BMC Remedy)?

Yes · via Custom Integration. Alerts + automatic tickets to NOC · familiar flow for your team · automated escalations per severity and carrier client.

does AstreaIoT monitor RF or backhaul?

No · RF/spectrum is the specialty of Anritsu, Viavi, Keysight. Backhaul fiber is NMS territory (SolarWinds, PRTG). AstreaIoT covers physical + environmental site infrastructure · network layer remains your NMS.

does it work in rural towers without internet?

Yes · gateway with cellular backhaul or solar for remote towers. Compatible with towers without own Ethernet. Some sites use the carrier's own backhaul.

is it billed per site or per portfolio?

Both · subscription per site (carriers or small tower companies) or per portfolio (tower companies with thousands of sites). Volume-tiered pricing.

is the carrier-client report pre-formatted?

Yes · pre-configured templates per carrier (Telcel, AT&T, Movistar) with uptime, events, evidence metrics. Per-site or per-portfolio downloadable PDF.

is site-operation confidentiality respected?

Yes · per-contract isolated per-site data · role-based dashboard access. For tower companies, carrier-client data confidential · access only to authorized team.

what if a site exits the portfolio (decommission)?

Sensors are portable · removed and mounted on new site in hours. No penalty · no de-installation fee. Redeployable hardware in the portfolio.

>./roi·VII · why this is good business

hundreds or thousands of sites · operated with data from the NOC.

site uptime
carrier SLA backed · generator always ready · copper protected · NOC with total visibility

For tower company or carrier, the ROI is the combination of guaranteed site uptime (carrier SLA backed), unnecessary site dispatches reduced (remote diagnosis), copper anti-theft (perimeter watched), and predictive generator + rectifier maintenance. A site down costs SLA penalty + thousands of users affected.

The winning argument is scale: one platform · hundreds or thousands of sites · NOC with unified dashboard. Technician dispatch to remote site without diagnosis (4-6 hour trip + on-site diagnosis) drastically reduced with remote data. Per-site measurable ROI.

The decision is not whether to invest; it is how much it costs not to when the next site falls from generator without fuel or the next copper theft in a remote tower without watched perimeter.

>./request-quote --vertical=telecom-towers-pops

your portfolio · operated from the NOC with data.

Thirty minutes. You tell us how many sites you operate (towers, POPs, ground stations), what carrier clients, what main priority (uptime, copper, generator, maintenance). We deliver a per-site quote + regional rollout plan.