what we protect · what we avoid.
- +More than two hundred thousand pesos saved per vaccine-refrigerator failure · the sensor costs a small fraction of the product it protects
- +PDF log in two clicks · 30 continuous days every 5 min for the COFEPRIS inspection under the FEUM Supplement
- +Gradual compressor degradation detected · 4-6 weeks before failure
- +Real-time informed decision during nighttime power outage: transfer product or wait
- +Humidity under control in coastal zones (Veracruz · Cancún · Mérida), logged for your inspection
- ✕Hundreds of thousands of pesos in biologics destroyed by one hour out of range
- ✕COFEPRIS fines + license suspension + sanction to the Responsable Sanitario's license card
- ✕Emergency compressor repair · several times the cost of preventive maintenance
- ✕Possible criminal investigation for nighttime-gap logbook
- ✕Test strips and powders lost to sustained coastal humidity
ten use cases · four critical areas.
for the responsable sanitario.
Farmacéutico Responsable + Quality Director. Three cases · each vaccine refrigerator, medication freezer, and biologic is worth more than the sensor that protects it — dual measurement (ambient + glycol) eliminates the surprise.
for the quality director.
Quality Director + Compliance + the Farmacéutico Responsable's license. Three cases · surprise COFEPRIS audit passes with immutable log ready in two clicks, not three hours of paperwork · coastal zones with humidity logged for inspection.
for maintenance.
Maintenance Lead + branch operations. Two cases · the compressor degrades 4-6 weeks before failure; the current meter detects it and enables scheduled maintenance · emergency repair avoided.
for the operations director.
Operations Director + Branch Director. Two cases · overnight area-wide blackouts and rollouts of hundreds to thousands of branches require operational continuity and executive visibility · the national dashboard surfaces patterns before they escalate.
three regulations · one platform covers all three.
If your branch is in a coastal zone, we automatically add dehumidifier activation when %RH crosses the label condition.
from sensor to report · every five minutes · without human intervention
Five steps. They run in parallel across all your sites, all the time. When something crosses a threshold, the flow completes in under five minutes — alert delivered, response logged, inspector-ready evidence captured.
measure
Sensors measure temperature, humidity, current, door-open, leak and other magnitudes every five minutes — no operator required.
detect
The system compares each reading against the threshold configured per recipe · per site · per equipment. Threshold crossing triggers the flow.
alert
The alert routes to the right person via WhatsApp, email or push · per role and schedule configured.
respond
The operator acts from the dashboard or mobile app. The corrective action goes into an immutable log with timestamp + signature.
audit
Everything becomes part of the audit package · time series, critical events, corrective actions, NOM report ready in two clicks.
Five steps · no manual operators · no paperwork · no gaps.
five phases · per branch.
branch site survey
1 dayTechnical visit + critical-equipment inventory + storage-point identification + per-branch checklist.
physical install
2-3 daysSensors mounted on refrigerators + freezers + storage + backup gateway · minimal cabling.
configuration + calibration
1-2 daysLabel-based thresholds · calibrated probes verified · COFEPRIS report template ready.
team training
1 dayResponsable Sanitario + Branch Manager + Quality Director · each role trains on their flow.
30-day support + first audit
30 daysAstreaIoT specialist available · first monthly log delivered · escalation chain tuned to real operation.
For chain rollouts with hundreds or thousands of branches: after the first site, phases compact to 4-7 days per branch with weekly waves.
common questions · before the quote.
what happens if the branch's internet goes down?
The gateway has 32-hour backup and a local buffer. Sensors keep recording · everything syncs on reconnect. If the outage is prolonged, the cellular backup takes over automatically.
can it connect to old refrigerators?
Yes. The sensors are external and mount on any equipment · no need to replace the refrigerator. The glycol probe slides through the door seal without modification.
how long does the inspection log take to assemble?
Two clicks. The system assembles it automatically with the selected 30 days, Responsable Sanitario's signature included. Print-ready or send-ready PDF in under a minute.
do I need my own internet connection?
Not required. The gateway uses the branch's WiFi when available (preferred for speed) · or the included cellular modem as backup. Works in branches without their own internet.
how are the sensors calibrated and how often?
At an accredited lab before deployment. Per-equipment vigency tracked in the dashboard. We remind you to recalibrate each probe per its certificate (12–24 months depending on use) and keep the certificate next to the log.
what happens if a branch closes or relocates?
We recover the equipment · no penalty, no de-installation fee. Sensors are designed to move · they can redeploy at the next branch with low friction.
does it integrate with the chain's ERP?
Yes · via Custom Integration. It connects to your ERP or your own system; each connection is sized in the assessment. Operational costs and critical alerts arrive directly to your central system.