LoRaWAN consulting and engineering

what to measure, with which sensor and where the gateways go.

Before a single sensor is installed we decide with you which point of your operation needs measuring, which device measures it well and how the signal gets out. That is project engineering: billed once, at a fixed price.

01

site survey

A visit to your site before we propose anything.

  • A technical visit to each site.
  • An inventory of the equipment to watch.
  • The critical points: where a failure costs product, time or an audit.
  • The standards that apply to your operation.
02

what to measure

The point, not the magnitude. Measuring “temperature” says nothing; measuring the product temperature does.

  • exampleIn a cold room, the product temperature, not the air by the door.
  • exampleOn a compressor, the current it draws, which changes before it fails.
  • Every point gets its threshold and the person in charge.
03

the recommended sensor

Always the one the manufacturer designed for that application. Never the cheapest one that “probably” works.

  • Range, ingress protection and power chosen by the point, not by the price.
  • If a point takes another device, the proposal labels it as an exception and says why.
  • The list describes what each sensor has to do, without brands.
What to measure at the point. At a cistern, the level, with a radar level sensor. In a cold room, the temperature of the product and not of the air, with a glycol probe. At an electrical panel, the current per phase, with a three-phase current meter. Never the cheapest one that “probably” works.THE POINTWHAT IS MEASUREDTHE SENSOR ITS MAKER DESIGNED FOR THATcisternlevelradar level sensorcold roomproduct temperature,not the airglycol probeelectrical panelcurrent per phasethree-phase current meterNEVERthe cheapest one that “probably” works
What to measure at the point. At a cistern, the level, with a radar level sensor. In a cold room, the temperature of the product and not of the air, with a glycol probe. At an electrical panel, the current per phase, with a three-phase current meter. Never the cheapest one that “probably” works.THE POINT→ WHAT IS MEASURED→ THE SENSOR ITS MAKER DESIGNED FOR THATcisternlevelradar level sensorcold roomproduct temperature, not the airglycol probeelectrical panelcurrent per phasethree-phase current meterNEVERthe cheapest one that “probably” works
Fig 1Three example points: what is measured at each and the sensor its maker designed for that.
04

coverage

The signal is measured on site, not assumed.

  • Coverage measured at each site, floor plan in hand.
  • How many gateways and where they go.
  • Cellular backup when the site has no reliable network.
  • The US915 band, the one used in Mexico.
05

integration

Which system receives what.

  • exampleTemperature excursions go to the WMS; the monthly report, to the ERP.
  • exampleCold-chain evidence for medicines goes to the HIS; the indicators, to your BI.

integration with your systems →

06

when the recipe does not exist

If your point has no recipe, we design it inside the project. What a second client also asks for goes into the platform for everyone.

  • The new recipe is defined during the survey, with its threshold and its report.
  • A decoder, firmware or a device nobody has integrated is custom LoRaWAN engineering: Astrea Technologies does that.

custom LoRaWAN engineering →

07

the deliverable

What you receive when the engineering closes.

  • A floor plan of the measurement points.
  • The sensor list, without brands.
  • Coverage: gateways, placement and backup.
  • A two-part proposal: the project and the platform.
08

billed once

At a fixed price, quoted after the site survey. The platform is separate, monthly per site.

  • Installation and go-live are in the same quote.
  • No billable hours, no surprise adjustments.
next step

let’s start with the site survey.

Tell us which operation you want to watch and how many sites it has. The first call is free.