NOM-213 · STPS · COFEPRIS

smoke-curing & charcuterie · every smokehouse · every curing room · every batch.

For Mexican smoked and cured meat processing (national meat processors and regional charcuterías CDMX/Mty + Tampico-style fish smoking + premium artisanal charcuterie). Four fronts: smokehouse 60-90°C cold smoke / 80-120°C hot smoke, weeks-long curing room 10-15°C / 65-80% RH, finished cold storage + operator air (CO₂ + TVOC) + CFE sub-metering. NOM-213 meats + NOM-251 + NOM-010-STPS-2014 + COFEPRIS.

what is at stake
smokehouse offsmokehouse 60°C instead of 80°C hot smoke target · undercooked charcuterie · botulism risk · NOM-213 + recall
weeks-long curingcuring room T+RH out of range over weeks · entire weeks-long batch lost · premium brand crisis
staff airaccumulated smokehouse smoke · exposed operators · NOM-010-STPS-2014 + chronic health
four critical zones · smoke-curing/charcuterie plant

four zones · complete plant.

A Mexican industrial smoke-curing and charcuterie plant has four operational fronts categorically different from other meat productions: precise smokehouse (cold smoke vs hot smoke), weeks-long curing room with precise T+RH, finished product cold storage + operator air (CO₂ + TVOC) + CFE sub-metering. AstreaIoT covers all four respecting the master charcutier's traditional recipes.

01

smokehouse · cold smoke 60-90°C / hot smoke 80-120°C

PT100 probe per smokehouse (cold smoke 60-90°C for hams + salmon / hot smoke 80-120°C for sausages + bacon) · continuous smoking curve log · WhatsApp alert to master charcutier if out of band · temperature probe from our catalog. Compatible with industrial smokehouses (national scale) and artisanal charcuteries (boutique premium).

02

precise weeks-long curing room T+RH

high-precision T+RH probe per curing room (target 10-15°C / 65-80% RH over weeks for serrano-style ham + prosciutto-style + salami) · continuous weekly log · cellar manager dashboard + WhatsApp alert to master charcutier if out of range. 6-18 month aging requires continuous surveillance.

03

operator air · CO₂ + TVOC (staff health)

air sensor (temperature, humidity, CO₂ and TVOC) in operator zone · threshold alert + an alert so your team ventilates. Smokehouse air with alarm and record: evidence for your NOM-010-STPS-2014 assessment.

04

finished cold storage + CFE sub-metering

T probe per finished-product walk-in cooler (target 2-7°C hams · 0-2°C fresh · -18°C frozen) · door sensor + compressor meter · NOM-251 cold chain logged. Main-panel meter with per-line CFE sub-metering + power factor.

Out of scope: cured-meat mixture formulation (that's your master charcutier). Also not the choice of smoking wood (mesquite, oak, apple, cherry) — that's tradition. Platform monitors smokehouse + curing + IAQ environment.

the platform · against five concrete losses

what we protect · what we prevent.

what we protect
  • +Smokehouse with precise curve · well-processed charcuterie · curve record for NOM-213 · botulism risk watched
  • +Monitored weeks-long curing room · defended weeks-long batch · defended premium charcuterie brand
  • +Operator air watched · protected operators · record for your NOM-010-STPS-2014 assessment · defended chronic health
  • +Validated finished cold storage · clean NOM-251 + COFEPRIS · defended brand reputation
  • +CFE sub-metering + power factor · consumption per line in plain view
what we prevent
  • ✕Smokehouse 60°C × 24h instead of 80°C × 24h hot smoke · undercooked charcuterie · Clostridium botulism · recall + brand crisis
  • ✕Summer curing room RH drops to 50% · 12-month prosciutto-style batch lost · catastrophic premium brand
  • ✕Smoke accumulated in operator zone · stale air without warning · STPS accident + investigation + chronic health
  • ✕Finished-product walk-in fails weekend · hams at 18°C · broken cold chain · NOM-251 compromise
  • ✕NOM-213 COFEPRIS audit without log · extensive investigation · brand value + recall
eight situations · four areas

eight use cases · four critical areas.

for the master charcutier + sanitary lead.

Master Charcutier + Sanitary Lead + Plant Manager. Two cases · hot-smoke smokehouse off-band during overnight cycle, cold-smoke smokehouse with low winter T. Botulism + profile.

#what happenshow we detectprotected value
01
Hot smoke smokehouse 80°C × 24h off-band (drops to 65°C overnight) · undercooked sausages/bacon · Clostridium botulinum risk · NOM-213 compromise + potential recall
smokehouse PT100 probe + continuous smoking curve log · WhatsApp alert to master charcutier · burner adjustment + cycle restart if necessary
Alert in time to correct the cycle · curve logged for NOM-213 · lower recall risk
02
Cold smoke smokehouse 65°C winter drops to 50°C · undercured ham · brand profile out of spec · boutique premium brand at risk
cold-smoke PT100 probe + continuous log · alert to master charcutier · wood adjustment
Defended brand profile · protected boutique premium brand

for the master charcutier + cellar manager.

Master Charcutier + Cellar Manager + Premium Director. Two cases · summer low-RH curing room with 12-month prosciutto batch, high-T curing room accelerates maturation. Aging + premium brand.

#what happenshow we detectprotected value
03
Curing room RH drops to 50% summer · prosciutto-style ham 12-month aging · excessive contraction + crystallized salt · entire 6-month aged batch lost · catastrophic premium brand
high-precision T+RH probe + WhatsApp alert to master charcutier · your team adjusts cooling and humidification
Defended 12-month prosciutto batch · protected boutique premium brand · preserved 6+ months of aging investment
04
Curing room T rises to 18°C summer · accelerated maturation + potential Listeria growth · 90-day salami batch with wrong profile
precision T probe · immediate alert so your team brings the temperature down
Defended salami batch · preserved cured profile · Listeria risk watched

for the safety lead + STPS lead.

Safety Lead + STPS Lead + Master Charcutier + Operators. Two cases · stale air in the smokehouse operator zone, chronic exposure to smokehouse smoke. Life + chronic health.

#what happenshow we detectprotected value
05
Stale air in the operator zone with several smokehouses at once · the operator walks in unaware
CO₂ and TVOC sensor in operator zone · immediate alert so your team ventilates before entering
Protected operator · record for your NOM-010-STPS-2014 assessment · accident avoided · investigation avoided
06
Chronic exposure to smoke from intensive smokehouse operation · operators with cumulative respiratory problems · pending SS investigation
CO₂, TVOC, temperature and humidity sensor in operator zone · continuous history per zone · base for improving ventilation
Documented exposure · base for smokehouse + ventilation improvements · defensible sustainability brand · long-term record for your NOM-010-STPS-2014 assessment

for the CFO + quality lead.

CFO + Quality Lead + Logistics Lead + Commercial Manager. Two cases · weekend finished-product walk-in fails, NOM-213 COFEPRIS audit without log. Cold chain + compliance.

#what happenshow we detectprotected value
07
Finished-product walk-in fails Friday night · hams + salamis at 18°C weekend · broken cold chain · Monday entire batch discard + potential recall
T probe + door sensor + compressor meter · immediate WhatsApp alert so your team acts
Saved finished product · Monday dispatch fulfilled · defended NOM-251 + cold chain · avoided recall
08
NOM-213 COFEPRIS audit without continuous log · extensive investigation · brand value + supply chain at risk
the time-stamped temperature record NOM-213 asks for · monthly smokehouse, curing and cold-storage report + exportable file for the inspector
Backed audit · protected brand value · complete log for the COFEPRIS inspection
regulations and compliance that apply

three compliances · one platform covers all three.

NOM-213-SSA1 · processed meats
what it requires
Meat products and byproducts: smokehouse curves + curing T+RH + cold chain + COFEPRIS audit.
how we deliver
smokehouse PT100 + curing T+RH + cold storage probes + log that can’t be edited · the record NOM-213 asks for, exportable for the inspector.
NOM-251 + NOM-010-STPS-2014
what it requires
Hygienic practices + assessment of smoke and chemical-agent exposure.
how we deliver
T probes + air sensor (CO₂ and TVOC) + exposure history · time-stamped record for your STPS assessment.
COFEPRIS + CFE GDMTO
what it requires
Federal sanitary + electrical-usage transparency (cold-storage + smokehouse compressors).
how we deliver
CFE sub-metering + power factor + CFO dashboard + monthly report.

For multi-plant production (multi-plant meat processors), comparison across plants with a score + exportable file per plant for the inspector.

>./workflow·how the data travels

from sensor to report · every few minutes · without human intervention

Five steps. They run in parallel across all your sites, all the time. When something crosses a threshold, the flow completes in under five minutes — alert delivered, response logged, inspector-ready evidence captured.

01

measure

Sensors measure temperature, humidity, current, door-open, leak and other magnitudes every few minutes — no operator required.

02

detect

The system compares each reading against the threshold configured per recipe · per site · per equipment. Threshold crossing triggers the flow.

03

alert

The alert routes to the right person via WhatsApp, email or push · per role and schedule configured.

04

respond

The operator acts from the dashboard or mobile app. The corrective action goes into a timestamped log with signature, which can’t be edited.

05

audit

Everything becomes part of the audit package · time series, critical events, corrective actions, NOM report ready in two clicks.

Five steps · no manual operators · no paperwork · no gaps.

five phases · from kickoff to first auditable batch

five phases · per plant.

01

site survey + plant plan

2-3 days

Technical visit + inventory of smokehouses (cold + hot), curing rooms (multi-month aging), walk-in cold storage, IAQ operator zone, CFE panel · deployment plan with NOM-213 + premium brand emphasis.

02

physical installation

2–7 days per site

Smokehouse PT100 probes + curing high-precision T+RH probes + air quality sensor + walk-in cooler probes + CFE meter · gateway with backup · without affecting production.

03

configuration + recipe integration

2-4 weeks

Per-recipe smokehouse curves (cold/hot smoke per product) + weekly curing room thresholds · temperature reports for NOM-213 + COFEPRIS · master charcutier's recipe respected.

04

team training

2 days

Master Charcutier + Sanitary Lead + Cellar Manager + Safety Lead + CFO + Operators · each role trains on their flow.

05

30 days of support + first audit

30 days

AstreaIoT specialist available · first monthly report with smokehouse + curing + IAQ + cold storage · first backed NOM-213 audit.

For multi-plant production, per-plant deployment with standardized BOM.

common questions before the quote

common questions · before the quote.

are NOM-213 audits specifically backed?

Yes · with the time-stamped temperature record NOM-213 asks for: monthly smokehouse, curing and cold-storage report + exportable file. Your sanitary lead hands it to the COFEPRIS auditor.

what does the air sensor in the operator zone measure?

Temperature, humidity, CO₂ and TVOC, from local stock. It goes in the work area, not inside the smokehouse. Placement is decided at the site survey.

does the PT100 probe continuously withstand smokehouse T?

Yes · temperature probe (operational 60-150°C) · smoke + temperature resistant cable · with a factory calibration report.

are master charcutier traditional recipes backed?

Yes · platform respects the historical range of each smokehouse + curing room that master charcutier has established. Alert only when something falls outside the range. The master makes decisions; the platform documents + alerts.

how is pricing for boutique charcuterie vs industrial production?

Scalable model: boutique charcuterie with 1-2 smokehouses + 1-2 curing rooms = accessible cost (15–30-day Hybrid Pilot). Industrial production (national meat processors) = enterprise scale with cross-plant dashboard. Approximately between several thousand and tens of thousands of pesos monthly.

is the "24/7 monitored charcuterie" brand narrative defensible?

Yes, with data: the temperature and humidity history of every smokehouse and curing room is stored, and you can share the report for each batch period with your customers. Defensible premium charcuterie brand vs industrial. Applicable to serrano-style ham, prosciutto-style, premium artisanal salami.

does it integrate with ERP systems (national meat processors)?

The platform sends signed events (webhook) to your ERP or your own system. Receiving data from your ERP we build with you as a project.

what is at stake

every smokehouse · every curing room · every batch.

~ $800K-$3M MXN/year per plant
approximately · protected value per mid-format smoke-curing/charcuterie plant · large producers (national meat processors) = between five and twenty million pesos annually · illustrative example

For a Mexican mid-format smoke-curing and charcuterie plant, annual protected value concentrates in four lines: weeks-long batches defended by monitored curing (a 12-month prosciutto-style batch can be worth millions), backed smokehouse (curve logged, lower recall risk), operator air watched (protected operators), backed NOM-213 audit (preserved brand value).

For multi-plant production (multi-plant meat processors), protected value multiplies with cross-plant dashboard + consolidated procurement + scalable premium brand narrative.

The decision for a smoke-curing/charcuterie plant is not whether to invest; it is when to start the pilot in the anchor curing room to accumulate protected value before the next weeks-long batch or COFEPRIS audit.

your charcuterie · every smokehouse, every curing.

Thirty minutes. You tell us your production type (industrial vs boutique artisanal charcuterie), number of smokehouses + curing rooms + cold storage, main products (hams / prosciutto-style / salami / smoked salmon). We deliver a quote + deployment plan + what is at stake with your numbers.